Dettagli


Acoustical operating principle Pressure gradient transducer
Directional pattern Omnidirectional, wide angle cardioid, cardioid, hypercardioid, figure-8
Frequency range 20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm 11 mV/Pa
Rated impedance 50 ohms
Rated load impedance 1 kohms
Equivalent noise level, CCIR1) 22 dB
Equivalent noise level, A-weighted1) 10 dB-A
Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 72 dB
Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) 84 dB
Maximum SPL for THD 0.5%2) 141 dB
with preattenuation -6 dB 147 dB
with preattenuation -12 dB 153 dB
Max. output voltage for THD < 0.5 % 10 dBu
Power Supply (IEC 61938) P48
Current consumption 3.2 mA
Required connector XLR 3 F
Weight 445 g
Diameter 64 mm
Length 145 mm
1) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
2) measured as equivalent el. input signal
Unità di misura | PZ |
---|---|
Disponibilità | 5gg lav. dall'ordine |
Produttore | Neumann |
Scrivi la tua recensione
Ogni utente registrato può scrivere una recensione. Per favore, accedi o registrati
Consegna in 5gg lav. dall'ordine significa che: l'articolo non è disponibile presso i nostri magazzini, verrà prontamente ordinato al nostro fornitore e sarà disponibile alla spedizione entro le tempistiche indicate, che corrispondono (in condizioni di normalità) ai tempi tecnici necessari. Tuttavia, le tempistiche non possono che essere indicative (specialmente se riguardano articoli che provengono da fuori il territorio Italiano), in quanto subordinate alla effettiva disponibilità nei magazzini dei nostri fornitori e anche ad eventuali contrattempi non inputabili alla nostra volontà.